The joist features 2 1 2 wide flanges for easier handling and more nailing glue surface and its uniform properties allow the joist to be installed with either flange up.
Fire proection for microlam floor joist.
Of the 2012 international residential code irc and thus providing an economical layer of fire protection.
However when a gypsum wall board ceiling is not a viable option roseburg rigidlam laminated veneer lumber lvl with a minimum cross section of 1 1 2 x 9 1 2 may.
Can prefabricated wood i joists be used without membrane protection.
Tj 9001 installation guide for floor and roof framing with tji 110 210 230 360 and 560 joists.
Microllam lvl laminated veneer lumber is one of the older trus joist products but is still a versatile performer in a wide range of structural applications.
Tj 9510 installation guide for floor and roof framing with tji s31 s33 and s47 joists east canada.
Section r302 13 exception 4 of the 2015 irc allows other approved floor assemblies demonstrating equivalent fire performance q.
A load bearing fire resistance test was carried out on a larger lvl beam spanning 4 m in a full size furnace following the iso 834 standard fire curve.
Each veneer is graded ultrasonically so the veneer mix can be tailored to meet the required design characteristics.
In addition to code compliant fire protection the flameblock i joist features easy installation and many product advantages.
Our most versatile beam solution.
Demonstrating equivalent fire performance.
Microllam lvl is engineered from large sheets of veneer laminated together to form a rectangular beam product.
The provisions call for installation of inch gypsum board 5 8 inch wood structural panel or other approved material on the underside of floor assemblies of buildings constructed under the irc.
Tj 9001p installation guide for tji 110 210 230 360 and 560 joists in punjabi language.
If the suspended ceiling system is fire rated as equivalent to the fire performance of 1 2 inch gypsum on the underside of the i joist framing it is considered an alternative to the fire protection requirements in accordance with the first paragraph in the 2015 irc section r302 13 and 2012 irc section r501 3.
Charring fire performance ignition laminated veneer lumber lvl 1.
Microllam lvl should only be used in dry interior use applications and should not be pressure treated.
Csg tjcan12 simpson connector guide for trus joist products.
Are there established criteria by which equivalent fire performance can be.
Introduction fire is one of the most unpredictable and dangerous accidents that may occur in our environment.
Lvl is not suitable for the pressure treatment process due to material density and glue lines.